Aerial view of a JCL substation transformer mobilization in progress
Proof in the field

Solutions in the Field

A look at the transformer and electrical equipment projects JCL has supported across the markets we serve, from standard equipment to highly specific applications.

The work

Every recent build

Large power transformer energized in a substation
In Production
Data CentersLatest build

AI cloud data center

Piscataway, NJ · Q4 2026

Four OLTC units feeding an AI cloud campus — engineered to the utility's interconnect requirements.

(4) 40/50 MVA69 kV – 13.2 kV
OLTCUtility interconnect
RenewablesIn Production

Utility-scale solar

Pekin, IL·Q2 2026

Twin collector step-ups for a utility-scale solar site, OLTC-equipped for the utility system.

(2) 27/35/45 MVA69 kV – 34.5 kV
OLTCUtility interconnect
RenewablesIn Production

Utility-scale solar

Pekin, IL·Q2 2026

Third unit on the same solar interconnect — 33/44/55 MVA with on-load tap changing.

33/44/55 MVA69 kV – 34.5 kV
OLTCUtility interconnect
Data CentersDelivering

Data center campus

Wytheville, VA·Q4 2025 – Q3 2026

Eight units for a single campus — first deliveries made Q4 2025, the balance lands Q3 2026.

(8) 30/40/50/56 MVA138 kV – 13.8 kV
Utility interconnect
Data CentersDelivered

Hyperscale data center

Rayville, LA·Q4 2025

Campus substation unit delivered to the utility interconnect schedule.

15/20/25 MVA34.5 kV – 13.8 kV
Utility interconnect
UtilitiesDelivered

Utility substation

Vineland, NJ·Q4 2025

138 kV OLTC unit built to a 650 kV BIL for a utility substation.

36/46/56 MVA138 kV – 13.2 kV
OLTC650 kV BIL
IndustrialDelivered

Industrial campus

Indiana·Q4 2025

Four matched units stepping 138 kV down to a 34.5 kV campus distribution system.

(4) 30/40/50/56 MVA138 kV – 34.5 kV
650 kV BILUtility interconnect
Data CentersDelivered

HPC / digital mining

Missouri·Q3 2024

Three units energizing a high-density compute site on the utility system.

(3) 30/40/50/56 MVA138 kV – 13.8 kV
650 kV BILUtility interconnect
Data CentersDelivered

Colocation data center

Allentown, PA·Q3 2024

36/46/56 MVA at 650 kV BIL for a colocation hall on the utility system.

36/46/56 MVA138 kV – 13.8 kV
650 kV BILUtility interconnect
IndustrialDelivered

Contractor-led build

Canton, OH·Q2 2023

Built alongside the site's electrical contractor — delivered ready to set and energize.

10/12.5/14 MVA69 kV – 12.47 kV
Utility interconnect
Data CentersDelivered

HPC / digital mining

Midland, PA·Q1 2023

Single 69 kV unit powering a high-density compute site — pad to power on one order.

30/40/50/56 MVA69 kV – 13.8 kV
Utility interconnect
IndustrialDelivered

Industrial site

Jenkins, KY·Q3 2022

69 kV to 13.8 kV site power for a heavy industrial load.

30/40/50/56 MVA69 kV – 13.8 kV
69 kV class
IndustrialDelivered

Contractor-led build

Nesquehoning, PA·Q1 2022

Two 115 kV units delivered through the site's electrical contractor — set, tested, energized.

(2) 30/40/50/56 MVA115 kV – 13.8 kV
Utility interconnect
Data CentersDelivered

Data center campus

Kansas City, MO·2025

Data-hall distribution at 415Y with sudden-pressure and winding-temperature protection spec'd in from the first drawing.

3,000 kVA34500D – 415Y
Sudden-pressure relayWinding temp indicatorCopper windings
UtilitiesDelivered

Electric cooperative

Central Florida·2025

Substation step-down bid with guaranteed load and no-load losses — the evaluation math you run is the performance you get.

7,500 kVA24940Y/14400 – 12470Y/7200
Guaranteed load lossGuaranteed no-load loss
Oil & GasDelivered

Gas processing site

Permian Basin, TX·2025

Step-up rated for generation duty, with K-4 harmonic capacity and an electrostatic shield for drive-heavy loads.

3,000 kVA34500Y/19920 – 480D
K-4 ratedElectrostatic shieldStep-up rated
Oil & GasDelivered

Midstream operator

Oklahoma·2024

A dual-voltage switch and custom tap arrangement let one unit follow the system through a voltage conversion.

2,600 kVA24940Y/14400 × 12470Y/7200
Dual-voltage switchCustom tap arrangement
RenewablesIn Production

Utility-scale solar

Desert Southwest·2026

Collector duty with three 2-position LBOR switches, a custom HV bushing chamber, and copper LV bus.

1,170 kVA11500D – 400Y
(3) 2-position LBORCustom HV bushing chamberLV copper bus bar
Oil & GasDelivered

Gas compression plant

Mountain West·2025

MIDEL synthetic fluid and an external fan package for hard-running 4,160 V compression loads.

5,000 kVA13800D – 4160Y
MIDEL synthetic fluidExternal fan packageWinding temp gauge
RenewablesDelivered

Community solar

Upstate New York·2025

Collector step-up with alarm contacts and a custom X/R ratio to match the interconnect study.

2,500 kVA34500D – 480Y
Alarm contactsCustom X/R ratio
IndustrialDelivered

Manufacturing plant

Gulf Coast, TX·2024

Copper windings in a NEMA 4 enclosure on anti-vibration pads — built for a washdown floor.

300 kVA34500Y – 600D
Copper windingsNEMA 4 enclosureAnti-vibration pads
RenewablesDelivered

Distributed solar

New England·2024

Alarm contacts and external-cabinet terminal blocks, finished in ANSI 70 light gray to the site standard.

1,000 kVA12470Y – 600Y
Alarm contactsTerminal blocks in ext. cabinetANSI 70 light gray
CommercialDelivered

Commercial development

Hudson Valley, NY·2025

A straightforward 13.8 kV to 480 V service unit — quoted, built, and delivered to schedule.

2,600 kVA13800D – 480Y
CommercialDelivered

Regional hospital

Greater Boston, MA·2024

Campus service transformer with the cutover coordinated around an occupied healthcare facility.

1,500 kVA13800D – 480Y
IndustrialDelivered

Industrial facility

Connecticut·2025

55/65 °C rise and 6% impedance to drop into the existing switchgear lineup without a coordination redo.

2,500 kVA13800D – 480Y
55/65 °C rise6% impedance
CommercialIn Production

Commercial facility

Farmington, NM·2026

Copper windings in FR3 natural-ester fluid for added fire safety at the service entrance.

2,000 kVA13800D – 480Y
Copper windingsFR3 fluid
Case studies

The full story on the hard ones

All case studies →

Fast-Track Power for a Hyperscale Data Center Hall

Hyperscale data center operator · Central United States · 8 × 3000 kVA

A hyperscale operator needed redundant transformer capacity for a new compute hall months ahead of standard OEM lead times. JCL pulled matching units from stock and ran phased delivery against the construction schedule.

Read the case study →

Substation Upgrade for a Rural Electric Cooperative

Rural electric cooperative · Midwest United States · 3 × 30 MVA

A rural electric cooperative needed to upgrade an aging substation to serve growing load before peak season — under a regulatory clock and OEM lead times that wouldn't make it. JCL matched stocked units to the existing infrastructure and delivered ahead of the deadline.

Read the case study →

Collector Substation for a Utility-Scale Solar Project

Utility-scale solar developer · Southwest United States · 2 × 75 MVA

A utility-scale solar developer lost their original transformer supplier mid-project and faced a commercial-operation deadline tied to their interconnection agreement. JCL sourced grid-tie units that met the interconnection spec and coordinated heavy-haul delivery to a remote site.

Read the case study →
Bring us the hard one

Got a complex one? Good.

The harder the spec, the more we want it. Tell us what you're up against — we'll tell you exactly how we'd build it.

300 kVA – 56 MVA
Unit range delivered
6
Markets served
24/7/365
Nationwide service